Latest New 2025 Model TURBO EXCEED SS V3+

Higher Output 22COP – High Efficiency, Low running cost (1kw Power Makes 22 Kw of warm water, oversized heat exchanger and condenser)

SILENT OPERATING 33 to 39 db – REAR DC FAN (Patented Rear Fan back discharge fan and dual side air intake)

25 year factory backed warranty

Stainless Steel Chassis for rugged Australian environment

Mitsubishi twin rotary compressor with 5 layer sound barrier jacket

AI CORE INVTR EXCEED Management Systems A.I.M.S - CORE INVTR optimises operation

TURBO XCEED INVTR SS V3

Key Features & Benefits:

COP22 Highest Efficiency Available

AI Core EXCEED TURBO Inverter Logic Technology Optimises Efficiency 120% Boost

AI CORE INVTR Smart Control Technology

Premium Build Quality and Long Factory Warranties

Ultra quiet 33 to 39 db - Asymmetrical Cowling SWIRLFLOW DC FAN

Powerful FRONT discharge SILENT Swirl IDEAL Flow Front AXIAL FAN

IDEALFLOW unique twisted TITAMIUM HEAT EXCHANGER

Advanced Heating Performance

Environmentally safe R32 Refrigerant. ( Higher Pressure more efficient)

Solar Connectivity PV options

Wi-Fi Klevaheat Heat Pump control via mobile app, easy to use from anywhere in the world

Smart Control Technology

Wi-Fi control via mobile app, easy to use

Solar Connectivity PV options

AI.M.S. EXCEED – AI-core inverter logic with 37 active functions

Noise Cancelling Mitsubishi twin rotary compressor & fan

Higher Output 18COP – High Efficiency,Low running cost (1kw Power Makes 18 Kw of warm water, oversized heat exchanger and condenser)

R32 refrigerant – environmentally-friendly produces 10% higher pressure saves money

Centri-Vortex Technology | COP22 Efficiency

The KH CFVX SSD V5+ is the 5th generation Centri- Vortex SSD heat pump, designed for maximum performance, energy efficiency, and ultra-quiet operation — all from a single side fan system.

7 mode maximum performance

ulltra-quiet operation

Mitsubishi twin rotary compressor
with 5 layer sound barrier jacket

High Density Twisted Titanium KLEVAHEAT Heat Exchanger

Specifications

Technical Range:
Single Phase Units: 7 kW to 28kW
Three Phase Units: Up to 41 kW

Model No.:TURBO XCEED INVTR SS V3 90 110 130 150 180
Refrigerant / R32 ENVIRONMENTALLY responsible
Power Supply / 380-415V/3N~/50Hz
Performance Condition: Air Temperature 27°C, Inlet Water Temperature 26°C, Humidity 80%
Heating Capacity kW 9.40 11.49 13.30 15.55 18.41
COP 22 W/W 21.80~7.18 22.08~7.27 22.13~7.11 22.06~7.10 22.05~7.19
Performance Condition: Air Temperature 15°C, Inlet Water Temperature 26°C, Humidity 70%
Heating Capacity kW 7.30 8.59 9.70 11.44 13.25
COP W/W 8.45~5.41 9.09~5.40 9.04~5.24 8.66~5.50 8.78~5.39
Acoustic Shield 5 layer Sound Cancelling Jacket
Wi Fi Standard WIFI Standard on all machines Third party wired connection too Automation Controller Enabled
CORE CONVERTER A.I.M.S. TECHNNOLOGY AI Powered AIMS Inverter Management System boosts performance to 22 COP with lowest power consumption
Heat Exchanger EXTRA CAPACITY Pure Titanium Twisted Double surface
area coil 30% more coils in Heat Exchanger for higher COP
Operating Air Temperature °C OPERATES FROM MINUS 20°C~43°C
Rated Power Input at 15°C kW 0.20~1.35 0.23~1.59 0.26~1.85 0.32~2.08 0.37~2.46
Compressor INVERTERTWIN TURBO / Mitsubishi Twin Rotary with SOUND CANCELLING 5 LAYER Jacket
Fan Motor / DC Top of range series semi commercial
Sound Level (1m) dB(A) 35.1~44.9 35.8~45.5 37.7~46.8 38.2~47.4 39.3~47.9
Sound Level (10m) dB(A) 15.1~24.9 15.8~25.5 17.7~26.8 18.2~27.4 19.3~27.9
Max. Current A 9.5 10.5 12.5 14.0 16.5
Advised Water Flow m3/h 4.0 5.0 6.0 6.5 8.0
Water Pressure Drop kPa 13 15 16 18 20
Water Connection 40HP mm 40mm High Pressure
Net Weight kg 63 64 65 70 74
Net Dimensions (L*W*H) mm 935*425*655 935*425*655 1055*425*685 1055*425*685 1055*425*685
Model No.:TURBO XCEED INVTR SS V3 210 250 280 320 400 P3
Refrigerant / R32 ENVIRONMENTALLY responsible
Power Supply / 380-415V/3N~/50Hz
Performance Condition: Air Temperature 27°C, Inlet Water Temperature 26°C, Humidity 80%
Heating Capacity kW 21.51 25.21 28.50 31.80 40.32
COP 22 W/W 22.05~7.17 21.92~7.31 22.15~7.07 22.03~7.11 22.10~7.05
Performance Condition: Air Temperature 15°C, Inlet Water Temperature 26°C, Humidity 70%
Heating Capacity kW 14.62 17.62 18.82 22.08 28.74
COP W/W 8.80~5.52 8.60~5.24 8.55~5.63 8.40~5.31 8.22~5.11
Acoustic Shield 5 layer Sound Cancelling Jacket
Wi Fi Standard WIFI Standard on all machines Third party wired connection too Automation Controller Enabled
CORE CONVERTER A.I.M.S. TECHNNOLOGY AI Powered AIMS Inverter Management System boosts performance to 22 COP with lowest power consumption
Heat Exchanger EXTRA CAPACITY Pure Titanium Twisted Double surface
area coil 30% more coils in Heat Exchanger for higher COP
Operating Air Temperature °C OPERATES FROM MINUS 20°C~43°C
Rated Power Input at 15°C kW 0.41~2.65 0.43~3.36 0.51~3.34 0.57~4.16 0.73~5.62
Compressor INVERTERTWIN TURBO / Mitsubishi Twin Rotary with SOUND CANCELLING 5 LAYER Jacket
Fan Motor / DC Top of range series semi commercial
Sound Level (1m) dB(A) 40.1~49.6 40.4~50.3 40.8~50.6 41.8~50.9 42.2~51.8
Sound Level (10m) dB(A) 20.1~29.6 20.4~30.3 20.8~30.6 21.8~30.9 22.2~31.8
Max. Current A 18.5 20.5 25.0 28.0 12.5
Advised Water Flow m3/h 9.0 11.0 12.0 13.5 17.5
Water Pressure Drop kPa 35 35 38 40 43
Water Connection 40HP mm 40mm High Pressure
Net Weight kg 86 100 104 123 147
Net Dimensions (L*W*H) mm 1215*425*761 1055*540*960 1055*540*960 1270*540*960 1345*540*960